7ae21b94-7e43-4641-81c8-0107282a9ebd

Indonesia Tier III Data Center Emergency Power Project

See how Haifeng Power help deploy five 1000kW diesel generator sets in parallel to establish a highly reliable backup power system that ensures zero downtime in case of utility failure of a data center.

1280X1280 (6)

Project Background

With the rapid development of Indonesia's digital economy and internet services, large-scale data centers have become critical infrastructure.

 

This project involves a core data center operated by a global cloud service provider. Built to Uptime Tier III standards, it demands N+1 redundancy, high availability, and seamless backup power capabilities.

The solution

5 × HF-1000GF Diesel Generator Sets

Engine: Cummins KTA50-G3 (renowned for stability and durability)

Alternator: Stamford HCI634F with PMG excitation and AVR regulation

Operating Mode: Auto Start, Auto Parallel, Auto Load Share

Output: 400/230V, 3-phase, 50Hz

Installation: Open-type with external soundproof enclosure integrated into the facility layout

83b3ea19-7b7f-4743-8f95-7d6b12843510
986f46a7-2513-4240-af4d-bedd61b74753
216a447a-bd5b-4018-97b5-704d5d83747e
6c90db68-696f-423c-bb82-7f7403997150

Haifeng Power’s Tailored Solution

  • 5 × HF-1000GF Diesel Generator Sets

    • Engine: Cummins KTA50-G3 (renowned for stability and durability)

    • Alternator: Stamford HCI634F with PMG excitation and AVR regulation

    • Operating Mode: Auto Start, Auto Parallel, Auto Load Share

  • Output: 400/230V, 3-phase, 50Hz

  • Installation: Open-type with external soundproof enclosure integrated into the facility layout

 

  • 5 Synchronization Panels equipped with:

    • DEIF AGC-150 series controllers

    • Automatic synchronization and load sharing

    • Redundancy rotation and fault bypass

    • Seamless integration with grid via ATS/MTS

  • Communication: Modbus TCP/RTU protocol, fully compatible with SCADA/BMS systems

 

  • Each unit features a 1000L base fuel tank, supporting 8–10 hours of continuous full-load operation

  • Central fuel system connection ports reserved for optional main tank integration

  • Automatic fuel level monitoring and low-fuel alarms ensure uninterrupted performance

 

  • Controllers support Ethernet/4G remote access modules

  • Site operators can monitor runtime, load, fault history, and fuel level via remote web interface or mobile app

  • Modbus/CAN bus communication enables seamless integration with centralized BMS/SCADA platforms

Need help? Book a call at a time to suit your schedule

Quisque velit nisi, pretium ut lacinia in, elementum id enim. Curabitur non nulla sit amet nisl tempus convallis lorem ipsum doror quis ac lectus. Proin eget tortor risus.